detection equipment in all rooms and areas of the household as follows: For minimum protection a smoke detector should be installed outside of each separate sleeping area, and on each additional floor of a multi-floor family living unit, including basements. The installation of smoke detectors in kitchens, attics (finished or unfinished), or in garages is not normally recommended.


For additional protection the NFPA recommends that you install heat or smoke detectors in the living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms, basements and attached garages.


Features:

Auto arm/disarm
Two independent partitions plus a common partition
Internet alarm reporting and uploading/downloading capability via on-board
Go to function to view or operate one partition from the other
AlarmNet Internet Communicator
Multiple actions on output devices depending on system state
Supports four graphic touchscreen keypads
Built-in phone line cut monitor with programmable delay and annunciation options
Supports a variety of wireless remote controls for single-button operation
Works with Sentrol CleanMe? maintenance signal
Wireless keys can be programmed without using zones
Flashes same lights when system is in alarm
Latchkey reports to pagers
Eight on-board hardwired zones standard (15 when Zone Doubling feature is used)
During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure.
40 hardwired expansion zones
Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes
Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio
Two low current on-board trigger outputs Viewable on system keypads: -Exit countdown -Time and date display* -Event log*
100 Event Log viewable at system keypads with time/date stamp
Programmable macro buttons and single-button arming
Trigger system bell Security Dealer Features
48 system user codes assignable to either partition
VIP Module allows system control from any touchtone phone
Expandable to 48 total zones when used with hardwired and/or wireless expansion modules
Global arming from any system keypad
Separate partition account numbers
16 output devices
Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10? devices (when used with a 4300 Transformer)
Supports four-wire, and up to 16 two-wire smokes
Turns lights off when system arms
Turns the same light on when system disarms
Display on system keypads
Trigger local sounders
Automatic System Load Shed
Reduces service calls to replace batteries.
Dynamic Signaling
Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio
Valuable End-User
Auto keypad backlighting on entry
Keyswitch arming
User Scheduling
Automatically activates X-10 and relays at programmed times
"User access" time windows
Supports up to four end-user numeric pagers
Chime by zone
Transformer Included

*Requires custom alpha keypad